Boost your preparation with the latest Engineering MCQs with answers and explanations. Our collection covers civil engineering, electrical engineering, mechanical engineering, electronics, software engineering, and other core subjects. These multiple-choice questions are designed for students, competitive exam aspirants, and professionals preparing for NTS, PPSC, FPSC, CSS, PMS, PEC exams, university entry tests, and job interviews. Practice online with updated Engineering MCQs to strengthen concepts, improve technical knowledge, and perform better in exams and recruitment tests.

794. What is the effect on the performance of the economiser in the thermal power plant boiler, if the feed water temperature is very low due to preheaters being out for repairs or starving of steam supply ?

A. It results in corrosion due to the condensation on the flue gas side of the economiser tubes due to handling of low temperature water
B. Economiser tube life increases due to handling of low temperature water
C. Heat transfer efficiency of economiser increases due to picking up high heat from the flue gases
D. Scale formation rate on economiser tubes increases
✅ The correct answer is option A.