Prepare with the best Chemical Engineering MCQs with answers and detailed explanations for exams and job tests. Our collection covers key topics such as chemical process calculations, thermodynamics, fluid mechanics, heat transfer, mass transfer, reaction engineering, instrumentation, and plant design. These Chemical Engineering multiple-choice questions are ideal for students, competitive exam aspirants, and professionals preparing for NTS, PPSC, FPSC, PEC exams, GATE, university entry tests, and job interviews. Practice online with updated Chemical Engineering MCQs to strengthen your concepts and improve technical problem-solving skills.

794. What is the effect on the performance of the economiser in the thermal power plant boiler, if the feed water temperature is very low due to preheaters being out for repairs or starving of steam supply ?

A. It results in corrosion due to the condensation on the flue gas side of the economiser tubes due to handling of low temperature water
B. Economiser tube life increases due to handling of low temperature water
C. Heat transfer efficiency of economiser increases due to picking up high heat from the flue gases
D. Scale formation rate on economiser tubes increases
✅ The correct answer is option A.