Prepare with the best Chemical Engineering MCQs with answers and detailed explanations for exams and job tests. Our collection covers key topics such as chemical process calculations, thermodynamics, fluid mechanics, heat transfer, mass transfer, reaction engineering, instrumentation, and plant design. These Chemical Engineering multiple-choice questions are ideal for students, competitive exam aspirants, and professionals preparing for NTS, PPSC, FPSC, PEC exams, GATE, university entry tests, and job interviews. Practice online with updated Chemical Engineering MCQs to strengthen your concepts and improve technical problem-solving skills.

4120. In case of design of a shell and tube heat exchanger,

minimum cleaning lane of 6.5 mm is provided, when tubes are on a square pitch.
minimum tube sheet thickness (in which tubes are fixed) is equal to the O.D. of the tube upto 15 mm tube diameter; and for > 15 mm tube diameter, tube sheet thickness is smaller than tube diameter.
O.D. of the tube is 6 to 40 mm while the tube lengths used are 0.5, 2.5, 3.0, 4.0, 5.0, 6 metres.
all (a), (b) & (c).
✅ The correct answer is option D.