Heat Transfer MCQs

144. In a laboratory test run, the rate of drying was found to be 0.5 x 10-3 kg/m².s, when the moisture content reduced from 0.4 to 0.1 on dry basis. The critical moisture content of the material is 0.08 on a dry basis. A tray dryer is used to dry 100 kg (dry basis) of the same material under identical conditions. The surface area of the material is 0.04 m²/kg of dry solid. The time required (in seconds) to reduce the moisture content of the solids from 0.3 to 0.2 (dry basis) is

2000
4000
5000
6000
✅ The correct answer is option C.

148. In a gas-liquid shell and tube heat exchanger, the

Presence of a non-condensible gas decreases the condensing film co-efficient
Gases under high pressure are routed through the tube side, because high pressure gases are corrosive in nature
Gases to be heated/cooled is normally routed through the shell side, because the corrosion caused by the cooling water or steam condensate remain localised to the tubes
All of the above
✅ The correct answer is option D.