2461. It is not recommended to use a 1-2 shell and tube heat exchanger for a particular heat duty, whenever the LMTD correction factor is > 0.75 < 0.75 < 0.50 < 0.25 ✅ The correct answer is option B.
2466. Which of the following accessories is provided in the vapor line of an evaporator for removing the entrained liquid? Bleed point Vent Catchall Baffle ✅ The correct answer is option C.
2468. Which characteristic of a fluid is not important in deciding its route in a shell and tube heat exchanger? Corrosiveness Fouling characteristic Viscosity None of these ✅ The correct answer is option D.
2471. For small temperature difference, the heat transfer rate as per Newton’s law of cooling is proportional to (where, Δt = excess temperature) Δt Δt² Δt³ √Δt ✅ The correct answer is option A.
2474. Double pipe heat exchangers are preferably useful, when High viscosity liquid is to be cooled Requirement of heat transfer area is low Overall heat transfer co-efficient is very high A corrosive liquid is to be heated ✅ The correct answer is option B.
2478. (Cp . μ)/K is termed as the __________ number. Grashoff Nusselt Prandtl Stanton ✅ The correct answer is option C.
2479. The advantage of using a 1 – 2 shell and tube heat exchanger over a 1 – 1 shell and tube heat exchanger is Lower tube side pressure drop Lower shell side pressure drop Higher tube side heat transfer co-efficient Higher shell side heat transfer co-efficient ✅ The correct answer is option C.
2462. The function of an economiser in a boiler is to preheat the Feedwater Combustion air Pulverised coal Furnace oil ✅ The correct answer is option A.
2472. Which is a regenerative furnace? Coke oven heating chamber Open hearth furnace Both A and B Neither A nor B ✅ The correct answer is option C.
2475. The heating capacity of muffle furnace depends on the Surface area & emissivity of the stock Properties of the muffle wall (temperature, area, emissivity) Both A & B Neither A nor B ✅ The correct answer is option C.